GILL SENSORS & CONTROLS: ADVANCED MEASUREMENT SENSORS
Main Menu
Gill offers a range of fuel level sensors designed for specific tasks: LevelPro, LevelLite, and LevelDefend
Gill fuel level sensors are designed for use with a wide range of fuels used in different application types.
These include petroleum (gasoline), diesel, kerosene based jet fuels including JP-5 and JP-8 and Avgas amongst others.
Our range of fuel level sensors uses highly dependable capacitive sensing technology, they provide reliable service in harsh environments where temperatures change and vibration is present.
Models are available to suit a range of tank depths and installation can be angled or inverted to suit compact or unusual installation types. Due to their design our fuel level sensors provide a damped response to reduce the effect of fuel sloshing when in mobile vehicles.
Level sensor description | Robust & reliable | Lightweight & precision | Military grade |
Typical use | Fuels, oils & coolants in commercial marine and off-highway | Fuels, oils & coolants in motorsport and UAVs | Fluids in mobile defence applications exposed to shock & vibration |
Construction | Stainless steel | Aluminium | Aluminium |
Outputs | 0.25-4.75V (max range 10V) or current 4-20mA | 0.25-4.75V (max range10V) + secondary output open collector | Current 4-20mA |
Accuracy | ±2% FSD @20°C | ±1% @ 50% FSD @ 20˚C | ±2% FSD @20ºC |
Resolution | 10 bit | 10 bit (1024 points over measurement range) | 10 bit |
Supply voltage | Voltage 5-32V DC Current 9-32V DC | 5-32V DC | 18-32V DC |
Supply current | <15mA | <20mA | >30mA |
Operating temperature | -40°C to +125°C * Refer to product datasheet for temperature derating | -40°C to +125°C * Refer to product datasheet for temperature derating | -40ºC to +85ºC |
Ingress protection | IP66, IP68 | IP68 | IP67 |
Mounting | SAE 5-bolt, 1.125” UNF, 1.25” BSP or 2” NPT thread options. Low profile sensor head with side cable exit (top exit 2″ NPT). | 1, 2, 3, 5 hole & M22x1.5 flanges. Low profile sensor head with side or top cable exit. | SAE 5-bolt. Low profile sensor head with side cable exit. |
Installation orientation | Top of tank or inverted | Top of tank or inverted | Top of tank or inverted |
Probe length | 100mm to 2000mm (in standard increments) | 100 to 750mm | From 100mm |
READ MORE › | READ MORE › | READ MORE › |